Sweden HM Carbide for cutting tools and HM Mechanical Properties, Chemical Element, Cross Reference, Datasheet.Stainless Steel, Special Steel, Compressor Blading, Turbine Blading, Superalloy Supplier.
HM can be supplied as steel plate sheet, round steel bar, steel tubepipe, steel stripe, steel billet, steel ingot, steel wire rods. Fm And Hm For R13 Materials Free Study MaterialsWe have provided all the downloadable free study materials and lecture notes download links. All the Subject names are listed below along with the links JNTUK B.Tech 2-1 Semester Civil Branch Notes. In addition to this, we also recommend preferring both textbooks and study materials which will help you to understand the concepts easily without any difficulties. Vote count: 5 No votes so far Be the first to rate this post. This became, and still represents, an acceptable level of fire risk. How Are Roofs Rated ASTM E108 defines fire test methods for roof coverings. These tests may be conducted at UL Inc., FM Global, or any other certified testing laboratory. E108 defines the following conditions: Over non-combustible roof decks such as steel, poured gypsum, or concrete, only the spread of flame on the top surface of the roof system is evaluated. The maximum flame spread is 6 feet for a Class A rated roof, 8 feet for Class B, and 13 feet for Class C. Gravel-surfaced built-up roofing and ballasted single-ply systems usually meet Class A, while mineral surfaced roofings may be Class B. Some unsurfaced systems, such as asphalt glazing, may be Class C or even unrated. If the roof deck is combustible, such as wood, plywood, or OSB, two additional tests must be conducted. Both are burn-through tests, and the ultimate roof systems rating is the lowest of the three tests. The burning brand: The brands consist of an ignited wood lattice placed directly on top of the test specimen. The Class A brand weighs 2,000 grams, Class B 500 grams, and Class C 9-14 grams. To meet Class A, the test specimen must resist 15 cycles, Class B eight cycles, and Class C three cycles. A one-hour rating would mean the structural elements have not yet reached their yield point when exposed to a under-deck heat load defined in ASTM E119 for steel structural members as reaching 1,070 degrees F. Interior fire hazard is evaluated by FM Global andor UL using differing test procedures. Both relate to a major interior building fire in Livonia, MI, back in 1953. In that case, an insulated steel building that might be expected to be highly fire-resistant failed catastrophically. Heat from an under-deck fire melted and vaporized the asphalt used to adhere the thermal insulation to a steel deck, feeding the fire. PageBreak Better Standards Rise from Livonias Ashes To understand better what happened in that fire, a test building was constructed, replicating the Livonia structure. The building, known as the White House (from where the White House Test is derived) was 100 feet long and utilized purlins, decking, and other parts that exactly matched the Livonia building. An under-deck fire was ignited at one end of the building, and the progression of the fire closely observed. A new deck providing more limited fuel burned end to end in 12 minutes, and a roofing and deck system with no vapor retarder and only narrow ribbons of asphalt used to adhere the thermal insulation to the deck burned in 13 minutes. The combustibility of all of these assemblies was considered unacceptable. When mechanical fasteners were used to attach the thermal insulation directly to the metal deck, the fire only spread 60 feet down the building during the 30-minute test burn.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |